Basic Info

Model No.: R407C

Product Description

Specifications 1.Replace for R22 in various air-conditioning application as well as in postive displacement Refrigerant systems.

 Physical properties
 Molecular formula    
 Mmolecular weight 86.20   
 Boiling point 101.3KPa(°C) -43.80   
 Freezing point 101.3KPa (°C) -  
 Density 30°C(kg/m3) 1129.30   
 Critical temperature (°C) 87.30   
 Critical pressure (MPa) 4.63   
 ODP 0.00   
 GWP 1700.00   
 
 Quality index
 Purity 99.8%
 Water content 0.001%
 Acidity 0.00001%
Evaporation residue 0.01%
 Chloride content 0.0001%
 Appearance Colorless and clear
 Odor  Odorless
Retrofit:
  1. Establish baseline performance. Note the oil type in use and any system operating  data (if system is operating properly). Check for existing leaks and identify any needed  repairs. 2. Recover the existing refrigerant charge (DO NOT vent to atmosphere). Weigh the  amount of refrigerant removed. 3. Drain existing oil from the compressor sump, suction line accumulators, etc. Record  the amount of oil removed. Add an equivalent amount of OEM recommended POE oil. 4. Recharge the system with the recovered R22 charge and run the system (at least 1  hour) to circulate the new lubricant. 5. Recover the R-22 charge again and check the residual oil content of the lubricant. The amount of the  original lubricant in the POE must be less than 5%. 6. Repeat steps 3 to5, as needed, until the required oil purity level is reached. Once the  oil flushes are completed, standard maintenance should be conducted (i.e. filter-drier change, leak repairs). 7. Evacuate the system (less than 500 microns) and ensure it maintains a vacuum. If  vacuum is lost, it may indicate that leaks are present in the system. 8. Charge system with R407C refrigerant. Remove refrigerant as liquid only from  cylinder. The initial charge weight should be approximately 90% of the standard charge  for R-22, charging up to 95% if necessary. 9. Adjust TXV set point and/or refrigerant charge to achieve the desired superheat. Low  side pressure control settings may also need to be adjusted. 10. Monitor oil level in the compressor. If necessary, adjust oil amount to attain normal  operating  level (mid-sight glass).
11. Label system clearly, indicating the type and amounts of system refrigerant and oil.    

Contact us if you need more details on R407 Refrigerant. We are ready to answer your questions on packaging, logistics, certification or any other aspects about R407c Efrigerant、Refrigerant R407C. If these products fail to match your need, please contact us and we would like to provide relevant information.