high purity r407 refrigerant mixed refrigerant gas

Basic Info

Model No.: R407c

Product Description

Specifications 1.Replace for R22 in various air-conditioning application as well as in positive desplacement refrigeration systems.

 Physical properties
 Molecular formula    
 Mmolecular weight 86.20   
 Boiling point 101.3KPa(°C) -43.80   
 Freezing point 101.3KPa (°C) -  
 Density 30°C(kg/m3) 1129.30   
 Critical temperature (°C) 87.30   
 Critical pressure (MPa) 4.63   
 ODP 0.00   
 GWP 1700.00   
 
 Quality index
 Purity ≥99.8%
 Water content ≤0.001%
 Acidity ≤0.00001%
Evaporation residue ≤0.01%
 Chloride content ≤0.0001%
 Appearance Colorless and clear
 Odor  Odorless
Applications: Applications include residential and commercial air conditioning systems, non-flooded evaporator chillers, and some commercial refrigeration systems. Since R-407C has similar properties to R-22, it is possible (with modifications) to use it in the same equipment designed for R-22 today.     Retrofit:
R-407C can be used to retrofit existing R-22 systems in positive displacement, direct expansion refrigeration, and air conditioning equipment.  R-407C should not be used in centrifugal chillers or other equipment that uses a flooded evaporator due,  to its high temperature glide.   Retrofit Procedure   1. Establish baseline performance. Note the oil type in use and any system operating data (if system is  operating properly). Check for existing leaks and identify any needed repairs.   2. Recover the existing Refrigerant charge (DO NOT vent to atmosphere). Weigh the amount of  refrigerant removed.   3. Drain existing oil from the compressor sump, suction line accumulators, etc. Record the amount of  oil removed. Add an equivalent amount of OEM recommended POE oil.   4. Recharge the system with the recovered R-22 charge and run the system (at least 1 hour) to circulate the new lubricant.   5. Recover the R-22 charge again and check the residual oil content of the lubricant. The amount of the original  lubricant in the POE must be less than 5%.   6. Repeat steps 3 – 5, as needed, until the required oil purity level is reached. Once the oil flushes are completed,  standard maintenance should be conducted (i.e. filter-drier change, leak repairs).   7. Evacuate the system (less than 500 microns) and ensure it maintains a vacuum. If vacuum is lost,  it may indicate that leaks are present in the system.   8. Charge system with R-407C refrigerant. Remove refrigerant as liquid only from cylinder. The initial charge weight should be  approximately 90% of the standard charge for R-22, charging up to 95% if necessary.   9. Adjust TXV set point and/or refrigerant charge to achieve the desired superheat. Low side  pressure control settings may also need to be adjusted.   10. Monitor oil level in the compressor. If necessary, adjust oil amount to attain normal operating       

Contact us if you need more details on R407 Refrigerant. We are ready to answer your questions on packaging, logistics, certification or any other aspects about R407C Refrigerant GasRefrigerant R407C. If these products fail to match your need, please contact us and we would like to provide relevant information.